These FEAS-Accumulator packs with electronic charging regulators are suited to buffer 24 Volt systems. They will ensure the power supply in case of a mains power failure and prevent the loss of your valuable data or the total breakdown of your production line. Regardless of for what you will apply the DC-UPS, you will always have the perfect protection against blackouts, which oftentimes can cause high costs.
- Switch-mode power supply with battery buffering / UPS
- Adjustable buffer voltage
- Adjustable buffer time
- Buffering of a consumer in the event of a power failure
- Integrated NiMH accumulator 0.72 Ah (exchangeable)
- Microprocessor controlled battery monitoring and charge status display
- Relay signals for mains failure, battery defect, overtemperature and battery voltage critical
- LED display for mains failure, overtemperature, overload, charging battery, accu alarm, buffer mode
- 50% overload over some time possible
- Extra low safety potential PELV (EN 60204), SELV (EN 62368)
- Short circuit, overload and open circuit proof
- Suitable for the tropics - epoxy resin casted
- Manual shut down in buffer mode “sleep mode”
- Buffer time terminable (1 up to 20 minutes and unlimited)
- Output separated according to VDE 0551
- Safety acc. to VDE, EN, UL, CSA
Battery replacement
To exchange the batteries, you will need: